Greetings!

New Content on eKnowledge

Product Support Alert - FLEX - microFLEX - J750 - UltraFLEX - Possible Issue with Microsoft Excel 2003 Service Pack 3 (SP3) re-image when using IG-XL V5.10.55_P9
The purpose of this PSA is to inform the field of a potential issue with IG-XL V5.10.55_P9 after a Z800 re-image.

Product Support Alert - UltraFLEX - IG-XL V8.10.00 Checkers Do Not Recognize HSD-U/UltraPin1600 as a Digital Instrument
The purpose of this PSA is to inform that in IG-XL V8.10.00 SW the UltraPin1600 (aka Utah aka HSD-U) is not recognized as a digital instrument during checker runs for certain instruments.

Application Support Bulletin: UltraFLEX UltraPin1600 Transition Guide (Revision B)
This bulletin describes the differences between the UltraPin1600 and the earlier HSD1000 and UltraPin800 digital instruments. It also covers guidelines for converting programs from the HSD1000/UltraPin800 to UltraPin1600. Finally, it presents guidelines for creating programs that use these instruments together on the same test system or that use these instruments in mixed configurations. This ASB is relevant to software versions IG-XL V8.00.01 and later. Revision A contains information on a pin assignment compatibility issue when developing test programs that use the UltraPin1600 together with either HSD1000 or UltraPin800 digital instrument boards. Revision B clarifies the scan depth specifications in the HSD1000, UltraPin800, and UltraPin1600 Feature Comparison table.

Product Support Bulletin - FLEX - Reference Clock Assembly Field Returns
The purpose of this PSA is to inform the field team of recent changes made to the FLEX Reference Clock Asssembly FRU (866-847-01).

Product Support Bulletin - FLEX - UltraFLEX - 2nd Update: Updated PSA for 974-366-03 SMC Assembly and Supporting Multiple System Types
This PSA supersedes or replaces the previous PSA versions sent out on this issue, PSA_100223 974-366-03 SMC Assembly and Supporting Multiple System Types and PSA_100512 Updated PSA for 974-366-03 SMC Assembly and Supporting Multiple System Types. This PSA is being updated due to the addition of a new system type, UltraFLEX XC, that requires a specific Support Cabinet Node SMC limit table and firmware to be installed.

Product Support Bulletin - UltraFLEX - FPGA Bitfile Updating & Test System Power Cycling
There have been some reported cases in which the end user has failed to cycle test system power after FPGA bitfiles were updated. This could possibly cause issues with the proper operation of the FPGA.

Product Support Bulletin - UltraFLEX - UltraFLEX User Guides Rev. 1219
This PSA informs that UltraFLEX-HD User Guide Rev. 1219, UltraFLEX-SC User Guide Rev. 1219, and UltraFLEX-HC User Guide Rev. 1219 are now available in eKnowledge.

Product Support Alert - FLEX - microFLEX - J750 - UltraFLEX - Implementation of MS Patch KB2597112 Can Cause Errors When Loading IG-XL
This PSA informs that it was determined that after Microsoft Patch KB2597112 was released that Teradyne tester computers that had patch KB2597112 implemented had problems loading IG-XL.

Product Support Bulletin - UltraFLEX - Annual Calibration of the UltraWave External Calibration Kit
This PSA informs that it was determined that after Microsoft Patch KB2597112 was released that Teradyne tester computers that had patch KB2597112 implemented had problems loading IG-XL.

Product Support Bulletin - PicoFLEX User Guide
The picoFLEX User Guide is now available in eKnowledge.

Product Support Bulletin - UltraFLEX - Recommended IG-XL versions for UltraPAC80 instrument
The intent of this PSA is to inform Teradyne field service engineers servicing UltraFLEX system that the UltraPAC80 instrument Rev Date 1144 and above requires the following IG-XL versions IG-XL V7.40.00 P10 IG-XL V8.00.01 P4 IG-XL V8.10.00.

Product Support Bulletin - UltraFLEX - UltraFLEX - Two Different Tools Needed to Support 810-736-00/01 UltraFLEX HC Testers

Product Support Bulletin - UltraFLEX - DC07 (UltraVI80) Checkers fail in 8.00.01 When No DSP Computer Installed
It was discovered that systems using IG-XL V8.00.01 or V8.00.01 P1 or V8.00.01 P3 or V8.00.01 P4 require that the DSP Computer Option be installed and functioning correctly in order for the UltraVI80 (DC07) checkers to successfully run.

UltraFLEX IG-XL V7.01.01 Variance List
This document contains the known and approved customer variances for IG-XL V7.01.01. Last updated 8/24/12.

Go to http://support.teradyne.com and log in to download this new content.


This notification is provided by Teradyne Semiconductor Test eKnowledge — adding value to the support we provide our customers.


Coming Up for Instructor-Led Online Training

Memory Test Basics (Sept. 25 and 27)
Jitter Measurements & Digital Undersampling on UltraFLEX (Taught in Mandarin) (Sept. 27)
Difference in Eagle Vision and Eagle Vision-MST (October 9, 10 and 11)

S-Parameter on UltraFLEX (October 16, 18 and 19)

All ILO Training Offerings