City Inspections
The City will continue to provide the following inspections for residential pools:
- 101 Building Layout
- 300 Electrical Slab (pre-pour)
- 302 Electrical Ground (pre-pour)
- 300 Electrical Slab (post-pour)
- 302 Electrical Ground (post-pour)
- 507 Plumbing Gas Yard Line (if pool is equipped with gas heater)
- 305 Final Electrical
- 521 Final Plumbing (if applicable for water protection device and/or a gas system)
- 112 Final Building
Following are changes to the 101 (Building Layout) and 112 (Final Building) City Inspections under the new code:
Layout Inspection
-
Obtain APSP 7, verify design total dynamic head (TDH) and design flow rate, upload to permit prior to scheduling inspection.
- Review pump information (pump curve required when pump can exceed design flow rate), upload to permit prior to scheduling inspection.
- Review and attach suction outlet fitting assembly (SOFA) information (shall exceed design flow).
-
Require that gauges be installed at suction and outlet side of pump to determine TDH at final inspection.
Final Inspection
- Obtain gauge readings and calculate actual TDH.
- Use pump curve and actual TDH to determine actual system flow rate.
- Compare actual system flow rate to SOFA flow rate (SOFA rate must exceed system flow rate).
-
Review Third-Party Inspection Checklist and compare with site conditions.