VOL XXV, ISSUE 4

 

Designing For the Next Generation

In the midst of the back-to-school chaos this month, we’re reminded just how fortunate we are to welcome students back to their school buildings at all. The COVID-19 pandemic resulted in countless shifts in our world, and leaving the classroom was one of them. But a silver lining that we've seen emerge is purposeful reinvestment in K-12 school construction and modernization. In part due to the availability of ESSER funds and other incentives, many districts have been able to either address critical maintenance issues facing their existing facilities, or in some cases, build entirely new schools. In fact, since 2020, our team has supported more than $220 million in K-12 construction and renovation across Iowa, South Dakota, Minnesota, and Wyoming. 


New or old, when it comes to designing schools, the student-centered approach isn’t just about creating a space for learning – it’s about creating an environment that supports health, safety, and diverse academic exploration. In this edition of Plains Talk, we’ll discuss our approach to designing that environment, as well as how we tackle the very real issue of managing costs. 


In This Edition


Review Before Renovations: White River School District


Student-Centered MEP Design Approach


Combatting Crowded Classrooms: Tri-Valley Elementary & High School


Making Good Bones Great: Lisbon High School


WPE News & Notables

Know someone who would benefit from our bi-monthly newsletter?


Click the button below to Subscribe on their behalf, or forward them this email and encourage them to check it out for themselves!

Subscribe!

Review Before Renovations

White River School District Master Plan & Renovations

If you've ever built anything, you know the adage - measure twice, cut once.

 

That same approach is valid when building and renovating facilities - especially schools. The White River School District in South Dakota recently began working with Co-Op Architecture to develop a comprehensive master plan to address the needs of students today, as well as to accommodate for growth and change down the road. By utilizing careful planning, the district will be poised for accurate decision-making.

 

West Plains Engineering joined the effort to assess the various existing mechanical and electrical systems for the existing elementary and middle schools. The goal of the study was to determine what, if any, systems needed to be replaced or updated and how that work fit into the plan for future building renovations and new construction.

 

Ultimately, these assessments were incorporated into the master plan, which recommended an addition to the elementary school, the design for which began in 2024. This project will add 10 classroom/support spaces, a music room, 2 public and 1 private restroom, custodial storage, and circulation space. In total, approximately 14,300 square feet will be added to the building.

 

The mechanical design for the addition has required careful phasing and a unique design approach. Under a separate project, the Department of Energy is working to upgrade the central boiler and chiller plant serving the district campus. With the elementary school addition being constructed simultaneously, the heating and cooling system had to be designed to operate with or without the central plant being online at any given moment.

 

To achieve this, the roof mounted air handling unit will be equipped with chilled water, heating water and air source heat pump coil capabilities, allowing the air handler to operate off the future central plant or as a stand-alone heat pump. In addition, an existing boiler system will be used to supply the air handling unit and associated variable air volume zone boxes with heating water, until the central plant is brought online.  

David Dowling is a Mechanical Designer in the Rapid City office of West Plains Engineering and has been heavily involved in the White River projects.


Email David

Student-Centered MEP Design

A modern student-centered design approach not only delivers space for learning – it holistically creates an environment that supports student health, safety, and diverse academic exploration. The MEP team is essential to delivering on that promise. Mechanical and electrical designers are responsible for developing effective, efficient air purification systems; delivering reliable, integrated building security, and creating flexible learning spaces that support today’s interactive, multi-faceted education.

Air Quality & Ventilation


Indoor air quality (IAQ) quickly became a post-pandemic design focus. We even dedicated an entire issue of Plains Talk to approaches for improving air purification and ventilation. Nearly 5 years later, IAQ remains at the top of a mechanical team’s HVAC design list. With asthma and allergies on the rise, specifying effective air filtration systems for K-12 continues to be crucial. High-efficiency filters and advanced purification technologies have been shown to significantly reduce airborne contaminants, creating a healthier environment for both students and staff. A healthier environment equals fewer sick days and a better opportunity to learn.


Among the most important considerations for designing K-12 air filtration include:


  • Selection of high-efficiency filters (MERV 13 or higher) for maximum contaminant removal
  • Design of filter housing and access for easy maintenance and replacement
  • Integration of advanced purification technologies, such as UV or bipolar ionization
  • Consideration of filter pressure drop and airflow rates for optimal system performance
  • Compliance with ASHRAE standards for indoor air quality


Safety & Security


Another hot button issue our society continues to confront is assuring school safety and security. This is where quality electrical design comes into the picture to implement surveillance, access control, and emergency notification systems.


Surveillance cameras and monitoring systems work in tandem with access control (card readers, door hardware, etc.) to keep a 360-degree eye on the building and its inhabitants. These systems can also be integrated into alarm systems and notification protocols to assure authorities are alerted quickly in case of emergency. To that end, emergency power and backup systems are also put in place to provide an extra level of reliability that all other safety systems will remain online.


Flexibility & Growth

Students today live in an increasingly interactive world. This includes the classroom, where audio-visual and telecommunication systems are simply par for the academic course in most districts. Not only that, but the space use for these rooms can vary based on the time of year or subject being studied. A room that is used for 3D art instruction in the Fall may shift to English literature in the Spring and so on.


Together, the mechanical and electrical disciplines must create environments that not only enhance the learning experience but are flexible enough to shift when that experience changes.


Electrically, this involves powering interactive whiteboards and LED displays, and sound systems and integrating networking solutions for content sharing and collaboration. It also includes considerations for room lighting and acoustics for optimal viewing and listening.


The mechanical team must do its part to assure flexible, customizable HVAC systems that offer consistent temperatures and air quality to support student comfort and focus – no matter how the space is being used.


Life Cycle & Cost

While there are dozens of MEP design considerations for K-12 spaces, it’s important to recognize those that most directly influence the student environment and learning experience. Equally, teams must consider how the systems they specify today will perform over time. Are they flexible enough to grow and change with the school’s needs? How does the cost of installation, operation, and maintenance impact the district’s budget planning? What is the overall life expectancy?


As part of the K-12 design process, we can provide a comprehensive Life Cycle Cost Analysis (LCCA) in order to arrive at the most cost AND performance effective system recommendations. Through this process, our team looks at the whole picture – from initial installation, through operation/maintenance, replacement and eventual disposal of the system. This 10,000-foot view allows us to compare different scenarios and design options, identify cost-saving opportunities, address maintenance and replacement schedules, and optimize building long-term sustainability. During this process, we can also research and review available tax incentives, utility rate structures based on system selection, and other avenues for savings that might influence final system selection and design. 

Article authored collaboratively by WPE engineers and staff.

Combatting Crowded Classrooms

Tri-Valley Elementary & High Schools

Like many districts in the region, Tri-Valley School District in Colton, SD began experiencing exponential student enrollment growth in the past few years. The existing school housed all grades K-12, and was becoming overcrowded for both teachers and students. Following a bond vote, the community endorsed the design and construction of both a new 97,000 square foot single-story elementary for K-4th grade, and a new 130,000 square foot high school.


The elementary school provides 5 kindergarten classrooms, 1 junior kindergarten classroom, 5 classrooms for each first through fourth grade, a music room, art room, multi-purpose room, kitchen, gymnasium, cafeteria, and support/storage/circulation spaces.


The two-story high school is 130,000 square feet and features a performing arts space with band and choir spaces, competitive gymnasium, auxiliary gym, and a wrestling room. The school also has a dedicated classroom wing, as well as areas for career and technical education, and the arts.


Since these buildings are in a rural setting, domestic water and natural gas utilities were a challenge. The water utility could not provide the volume or pressure required for the new building, so a domestic water storage tank was provided in the building to provide a buffer in volume during periods of high water demand. Also, a pressure booster pump was added to provide adequate pressure to all plumbing fixtures and equipment in the building.  For natural gas, the cost and design to run natural gas 2 miles from the nearest utility line was coordinated with the utility, as the school did not want propane tanks. The school will receive credits in the future for all rural customers who tie on to this line.


The K-4 building was completed and welcomed students in the Fall of 2023, while the high school is currently under construction expected to be completed by the end of the year.

Stuart Oster, P.E. is head of the Mechanical Department in Sioux Falls and was the MEP Project Manager for both the Tri-Valley Elementary and High School projects.


Email Stu

Making Good Bones Great

Lisbon High School Addition & Renovation

Not all schools need to start over from scratch. A good portion of our educational resources in this region are in good shape - they just need a few upgrades and addition to make sure infrastructure continues operating at peak efficiency and performance.


We recently worked with the Lisbon Community School District in Lisbon, IA on a $5.4 million addition and renovation to the existing high school. The district wanted to expand student resources, and opted to add a weight room, as well as a Career and Technical Education (CTE) wing and additional classrooms. In total, the project added 13,000 square footage to the existing building, and renovated additional spaces.


The new classroom addition utilized variable refrigerant flow (VRF) fan coils systems for heating and cooling with a dedicated outdoor energy recovery unit for ventilation. The VRF system included electric supplemental heat for the fan coil units.


In addition to the MEP work for the new spaces, our team upgraded the HVAC serving the existing gymnasium. The gym was previously only heated, so a new rooftop unit was installed on the weight room roof with distribution ductwork to provide heating and cooling. Notably, the RTUs for the gymnasium and weight room were able to be purchased separate from the project using ESSER funds. The facility also had an existing steam boiler that was inefficient, oversized, and required significant maintenance. This unit was decommissioned, and the existing spaces were converted from steam to hot water heating.  

Mike Drahos, P.E. is an Office Manager and Mechanical Engineer in Cedar Rapids. He was the Project Manager and led the mechanical design for this project.


Email Mike

WPE Projects in the News

Check out some of our projects featured on social media and the news!

Chamberlain Elementary School

Chamberlain, SD

One Stop Government Office Building

Sioux Falls, SD

SDSU First Bank & Trust Arena

Brookings, SD

DSU Athletic Complex

Madison, SD

DSU Madison Cyber Labs

Madison, SD

Boston's Pizza Restaurant

Casper, WY

WPE Sponsors AIA-SD Design in the Hills

It was our priviledge to sponsor the AIA-SD Design in the hills for the 8th consecutive year in 2024! It's always a pleasure to spend the day with our architectural teammates West River and learn about the area's interesting new spaces.

Welcome to WPE!

But Wait...There's More!

If you aren't currently following us on social media, you're missing out on daily updates from around our company (plus a few clever memes and wacky anecdotes for good measure).


Click any of the social icons below to see what we've been up to recently and don't forget to Like or Follow!

Facebook      LinkedIn      Instagram
 
 
Rapid City, SD  |  Sioux Falls, SD  |  Casper, WY  |  Cedar Rapids, IA
CHECK US OUT ONLINE
Facebook  Linkedin  Instagram
SUBSCRIBE
Visit our website