An example of a finding at MM.06.01.01 EP 3: ”In review of the record it was noted the patient had an order for PRN medication for mild pain and PRN medication for severe pain. The record indicated two different instances in which the patient received the PRN medication for severe pain. Documentation did not reflect a pain scale. This was observed by staff assisting with record review.” This finding was scored as Moderate/Pattern.
IC.02.02.01 EP 2: Of four instrument trays inspected in Sterile Processing that were assembled awaiting sterilization, had been sterilized, or just used in the OR being cleaned in decontamination, it was noted that 3 of the 4 trays had plastic tape labels that were degraded, chipped, and or with tape adhesive exposed that should not have been accepted for use in the OR. A 4th tray, labeled Small Bone tray, contained an instrument (tissue elevator) that was visibly pitted/excoriated that should not have been included in the assembly of the set for use in the OR. This was confirmed with the Manager of Sterile Processing and the Director of Surgical Services. This finding was scored as High/Widespread.
IC.02.02.01 EP 4: During tracers in a C-section room that was identified as ready for use, it was noted that clean patient care supplies were stored directly on the floor. For example: Clean/new oxygen tubing, suction cannister, SCD machine. This was confirmed by unit director. This finding was scored as Moderate/Limited.
The best way we know to mitigate these high-risk findings is to be diligent with surveillance rounds and ensuring the staff members at the point of use know the standard and understand how the standard is surveyed. In other words, what we find frequently is that staff at the point of use do not know how to identify an instrument that should not be used for a procedure, or they do not have options for replacement. We have performed numerous focused tracers and assist visits on this very topic.
|