https://www.datavisionimage.com/

208-286-7588

7 Preventable Signature Recognition Errors


Part 2

SIGNATURE VERIFICATION SYSTEM

This series of emails will explain why many Signature Recognition Systems don’t work as well as they should and suggests you look at our Identi-Sig based Automatic Signature Recognition and Verification Solution. Our Identi-Sig process can be added by your vendor to their algorithms to dramatically improve performance. Better yet, you can simply purchase or rent our automated program and immediately improve your ability to detect a fraudulent signature. DATAVISION has determined there are at least seven basic faults in existing signature recognition systems. This series of emails will explain each problem area and how the Identi-Sig process corrects these errors in some detail. It’s going to take a few mailings to do this. 


In our previous email we noted many Signature Recognition Systems use the underlying Central Limit Theorem statistical assumptions incorrectly. We also noted that people don’t sign the same name each time they sign. Some early Signature Recognition Systems that are based on using only a single master signature will break down because of this. 


Today we want to discuss two more important considerations that many Signature Recognition Systems may not be applying correctly.


Problem 3. Adjustable Acceptance Limits Not Available

 

Most Signature Recognition Systems return a score indicating how well the sample signature matches the master signature. Unfortunately the user has little influence on this score because most systems do not allow the user to determine the ideal score for their unique situation. In some cases it may be determined that satisfying half of the algorithms almost always produces a correct result, while in other times, 80% or more of the algorithms must be satisfied. If the score set by the vendor is too low then the system will report some bad signatures as good, and if the score is too high then the system will report some good signatures as bad.


The Identi-Sig process uses an adjustable threshold control so the score necessary to obtain ideal results can be adjusted by the user. As can be seen in Figure 1, the Acceptance Score (set at 70 percent) is easily adjusted.

Figure 1. An acceptance score of 70% has been set by the user

Problem 4. Unless thousands of samples are used, it is highly unlikely the distribution of bad matches and the distribution of good matches can be accurately measured to determine if this algorithm is producing a valid result.


Wow, what a mouthful! Let me try and simplify this very important concept.


Let us assume you could gather 100 volunteers to provide a sample of their signature. Let us further assume you asked each volunteer to provide 10 samples of their signature. Then you could do the following:


Begin by assigning a four digit number starting with 0001 to the first volunteer, 0002 to the second, and continue to 0100 for the last volunteer. For each of the ten signature images number them 0 through 9. The ten matching images from the first volunteer would be labeled 00010 through 00019.


If you matched each image against another from the same signer you would end with 45 different matches. With 100 volunteers you would have 4500 different matches of similar signatures. Not a great volume for AI purposes but read on.


With 100 volunteers you would have 1000 signature images, most of which would not match each other. That is, with just 100 volunteers you could have 990,000 trial matches, considering 1000 images taken two at a time. Let’s just round this to a million to keep it simple.


Identi-Sig has 57 algorithms. For images that do not match one another, each algorithm could produce one million data points. Considering all 57 algorithms you could produce 57 million data points, a good number for AI to use.


As an example of how this works, let’s compare image 00010 to image 00013. We know they come from the same signer because the first four numbers of the image match. Let us introduce these two images to one algorithm. Let us assume the first image (call it the master) produces a value of 452. Let us assume the second image (call it the sample) when processed by our algorithm produces a value of 512.


The second value of 512 would be considered the same as the first value of 452 if the range permitted were 512-452 = 60 or 60/452=14%. In other words, if the master and sample value were within 14% of each other they match.


Save that range number and repeat this procedure 4500 times, drawing randomly from numbers that are from the same signers. A computer program can do this in a few seconds.


If you plot the numbers on a graph then the central Limit Theorem states the distribution will look like Figure 2.

Figure 2. Distribution of good ranges.

 

Let’s do the same thing with the images that don’t match. With 1000 images taken two at a time we get 990,000 combinations (let’s round it to one million for illustration purposes). We would get a very good normal curve like shown in figure 3.


Figure 3. Distribution of bad ranges.


Now let’s put these two curves on the same scale as shown in figure 4.

Figure 4. Distribution of good and bad ranges.


Looking at the graphs in figure 4, we can now see if the range between the master value and the sample value were within the good distribution it would be good, and if it fell within the range for the bad comparisons, it would not be a match. Identi-Sig was tested using these concepts and achieved a 99% correct recognition rate.


Sometimes we might find a particular algorithm produces a graph of ranges as shown in Figure 5. As you can see there are some ranges that overlap. In this case a particular value could be from a good range distribution or a bad range distribution. We’ll discuss how to mange this case later in this discussion

Figure 5. Distribution of overlapping good and bad ranges.

 

The last concept to illustrate here is the concept of variance. Variance measures how tall or how flat a normal curve is. This is shown in Figure 6.


Figure 6. Small vs Large range variance normal curves.


The smaller the range variance, the more accurate the algorithm. The greater the distance between ranges for good and bad, the more accurate the algorithm. These are important concepts when we discuss the reality that not all algorithms produce equally reliable or valid results.


Now that we have established how to obtain 57 million data points and how to plot these data points to form two very reliable range distributions, we can discuss how Identi-Sig applies these concepts to improve the signature recognition predictions. We will do that in the next email.


We'll be sending you additional information about the 7 preventable errors in most signature recognition systems in the coming weeks. To discuss how DATAVISION can help or to get a complete copy of this series of emails, please call or contact us by clicking on the button or links below.

Contact Us For Free Demo


  Watch a nine minute video

 

DATAVISION IMAGE LLC Website