The patented design and control of the Vector AR lip sets it apart from traditional dual A/R lips. All essential setup parameters are displayed and (in most cases) adjusted on the ITALYCS HMI screen. The secondary collar and Vector Ring are positioned repeatably with servo drives. The lower orifice can be adjusted while the line is running, without disturbing the bubble, and its position is displayed on the HMI screen. (the adjustment is made by turning the knob under the A/R – positioned in an accessible spot)
The air flow rate, pressure, and air temperature in the inlet duct is continuously measured and displayed. All these parameters can be saved in a recipe for the film, and recalled later for exact repeatabilty. ITALYCS’ trending function can be used to review the history – see more in the Trending page.
The streamlined air flow channel and patented Vector Ring make this A/R easier to operate and optimize, and perform better with a wide range of film types.